技术属性

一般信息
Product type Power and control cable
Copper index 21.600  kg/km
Copper index (lb) 145.130  lb
Weight 80 kg/km
电气特性
Nominal voltage U0/U: 300/500 V AC rms according to IEC
Max. conductor resistance at 20°C 26  Ω/km
Test voltage 3  kV
Current rating according to VDE 0298-4
产品设计
Conductor design IEC 60228 class 5: fine-wire
Conductor material Bare copper
Harmonised design H05BQ-F
Min. outer diameter 6.2
Nominal conductor cross-section (metric) 0.75  mm²
Cable dimension 3G0.75
Shielded

Core identification Colours
Shape of cable Round
Outer sheath colour orange
Stranding type Layered stranding
Cable sheath RAL colour RAL 2003
Conductor colour code VDE 0293-308
Number of cores 3
Core insulation basic material Ethylene propylene diene rubber
Basic material of outer sheath Polyurethane
Including protective earth

Core insulation basic material, short form EPDM
Max. outer diameter 8.1
Basic material of outer sheath, short form PUR
产品特点
Flame-retardant

PWIS-free according to VDMA 24364-B2-L
Storage temperature min. -25
Chemical resistant

UV-resistant

hydrolysis resistant

Minimum bending radius in mm, fixed installation 32.4  mm
PWIS-free

Application area Flexible, Fixed installation
max. conductor temperature, occasionally moved -40 °C to 90 °C max. conductor temperature:
Oil-resistant

Max. storage temperature 55
Minimum bending radius in mm, occasionally flexing 101.3  mm
weather resistant

Minimum bending radius, stationary 4 x outer diameter
Minimum bending radius, occasionally flexing 12.5 x outer diameter
Temperature, fixed installation -50 °C to 90 °C max. conductor temperature:
Oil resistance according to EN 50363-10-2
UV-resistant according to EN ISO 4892-2, method A (colour change permitted)
Halogenfree

认证和标准
cUR recognized

CSA certified

Product standard DIN / EN EN 50525-2-21
HAR-certified

Ecolab certified

cUL listed

Flame retardance tested according to UN/ECE-R118

UL listed

CE marked

UL recognized

VDE certified

EAC certification number ЕАЭС N RU Д-DE.АЮ64.В.00130/20
EAC-certified

文档
Notes
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Trade product, not a LAPP product.
产品系列列表
All articles from H05BQ-F / H07BQ-F
Article number Number of cores Including protective conductor Conductor cross-section (mm2) Nominal voltage Imp outer dia cable sheath min Imp outer dia cable sheath nom Min. outer diameter Nominal outer diameter Imp outer diam cable sheath max Max. outer diameter Copper index calc export Weight
0013600 2 No 0.75 U0/U: 300/500 V AC rms according to IEC 5.7 7.4 50 kg/km
0013601 3 Yes 0.75 U0/U: 300/500 V AC rms according to IEC 6.2 8.1 80 kg/km
0013610 2 No 1 U0/U: 300/500 V AC rms according to IEC 6.1 8 60 kg/km
0013611 3 Yes 1 U0/U: 300/500 V AC rms according to IEC 6.5 8.5 74 kg/km
0013620 2 No 1.5 U0/U: 450/750 V AC rms according to IEC 7.6 9.8 87 kg/km
0013621 3 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 8 10.4 108 kg/km
0013630 2 No 2.5 U0/U: 450/750 V AC rms according to IEC 9 11.6 90 kg/km
0013631 3 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 9.6 12.4 161 kg/km
00136023 4 Yes 0.75 U0/U: 300/500 V AC rms according to IEC 6.8 8.8 78 kg/km
00136033 5 Yes 0.75 U0/U: 300/500 V AC rms according to IEC 7.6 9.9 98 kg/km
00136123 4 Yes 1 U0/U: 300/500 V AC rms according to IEC 7.1 9.3 92 kg/km
00136133 5 Yes 1 U0/U: 300/500 V AC rms according to IEC 8 10.3 114 kg/km
00136223 4 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 9 11.6 137 kg/km
00136233 5 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 9.8 12.7 165 kg/km
00136323 4 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 10.7 13.8 206 kg/km
00136333 5 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 11.9 16.3 254 kg/km